Integrated Field Monitoring of Paramedic Workload and Exposure A Multi-Modal Methodological Study

Main Article Content

Alex MacQuarrie, RP, PhD
Matt Stainer, PhD
Eric Drinkwater, PhD
James Crane, PhD
Peter Micalos, PhD
James Wickham, PhD

Abstract

Introduction: Paramedics experience demanding physical tasks, acute stressors, and chronic under‑recovery, defined as an accumulation of incomplete physiological and psychological recovery. However, occupational exposure research has primarily relied on retrospective self‑report, simulation, or single‑modality monitoring that poorly capture within‑shift variation and operational context.


Objective: The objective of this paper was to describe, implement, and evaluate a field-embedded, multi-modal protocol for measuring paramedic occupational exposure across routine rostered shifts, cross-referenced to CAD data. Specifically, we report protocol feasibility, data completeness, artifact burden, and field validity as methodological endpoints.


Methods: We conducted a prospective methodological observational study embedded in the routine operations of a large Australian ambulance service. A workforce‑aligned sample of operational paramedics completed multiple monitored shifts wearing Hexoskin smart garments for continuous heart rate, respiratory rate, and accelerometry data, with pre‑/post‑shift and pre/post call blood pressure measurement and Borg Rating of Perceived Exertion (RPE) where feasible. Anonymized computer-aided dispatch (CAD) records provided call type, priority, and phase timestamps (assign, en route, on scene, to hospital, at hospital), enabling minute‑level linkage with biometric data. Standardized procedures were specified a priori for recruitment, device fitting, shift monitoring, logbooks, data export, cleaning, missing‑data thresholds and an epoch‑based hierarchical data structure (epochs within calls, calls within shifts, shifts within paramedics). Primary procedural endpoints were feasibility and adherence, data completeness and artifact profile, and field validity of Hexoskin measures.


Results: Thirty-two paramedics completed 232 monitored shifts, yielding 918 emergency calls and approximately 2,700 hours of analyzable multi modal monitoring. Protocol adherence was high, with most rostered monitoring opportunities proceeding as planned and shifts meeting the predefined ≥75% biometric data completeness threshold despite approximately 5% of ECG data being removed as artifact. Hexoskin heart and respiratory rate patterns demonstrated expected gradients across CAD-defined call priorities and operational phases. They were consistent with prior laboratory validation, supporting the field validity of the protocol.


Conclusions: This protocol provides a replicable, EQUATOR‑aligned framework for multi‑modal paramedic exposure research that could be adapted to other emergency services. By foregrounding design, measurement, data processing, and analytic structure, it provides methodological infrastructure to support future etiologic and intervention studies.

Article Details

How to Cite
MacQuarrie, A., Stainer, M., Drinkwater, E., Crane, J., Micalos, P., & Wickham, J. (2026). Integrated Field Monitoring of Paramedic Workload and Exposure: A Multi-Modal Methodological Study. International Journal of Paramedicine, (16), 38–46. https://doi.org/10.56068/CIDO0526
Section
Research Reports

References

Alenazi, S. K., Al Otaibi, B., Alenaz, A. N., & Alrashidi, Q. S. (2016). Stress and burnout among Red Crescent paramedic ambulance workers in Riyadh. Journal of Emergency Medicine, Trauma and Acute Care, (2), 67. https://doi.org/10.5339/jemtac.2016.icepq.67

Babangida, A. A., Caraballo-Arias, Y., Decataldo, F., & Violante, F. S. (2025). Advancing occupational medicine through wearable technology: A review of sensor systems for biomechanical risk assessment and work-related musculoskeletal disorder prevention. ACS Sensors, 10(8), 5410-5432. https://doi.org/10.1021/acssensors.5c01578

Borg, G. A. V. (1982). Psychophysical bases of perceived exertion. Medicine & Science in Sports & Exercise, 14(5), 377???381. https://doi.org/10.1249/00005768-198205000-00012

Buljan, D., Drozd, A., Madziala, M., & Aleksandrowicz, S. (2016). Intensity of stress and symptoms of job exhaustion among paramedics in Poland. Disaster and Emergency Medicine Journal, 1(1), 43–49. https://doi.org/10.5603/demj.2016.0007

Cherif, N. H., Mezghani, N., Gaudreault, N., Ouakrim, Y., Mouzoune, I., & Boulay, P. (2018). Physiological Data Validation of the Hexoskin Smart Textile. Proceedings of the 11th International Joint Conference on Biomedical Engineering Systems and Technologies, 150–156. https://doi.org/10.5220/0006588001500156

DeMers, D., & Wach, D. (2025). Physiology, mean arterial pressure. National Library of Medicine.

Elliot, C. A., Hamlin, M. J., & Lizamore, C. A. (2019). Validity and reliability of the hexoskin wearable biometric vest during maximal aerobic power testing in elite cyclists. Journal of Strength and Conditioning Research, 33(5), 1437–1444. https://doi.org/10.1519/jsc.0000000000002005

High, R. (2015). Demographics of NSW ambulance paramedics. In A. MacQuarrie (Ed.), (email ed., pp. 1). NSW, Australia.

Hunter, J. R., Macquarrie, A. J., & Sheridan, S. C. (2019). Physical capacity of New South Wales ambulance paramedics. Occupational Medicine. https://doi.org/10.1093/occmed/kqz131

Janka, A., & Duschek, S. (2018). Self-reported stress and psychophysiological reactivity in paramedics. Anxiety, Stress, & Coping, 1-16. https://doi.org/10.1080/10615806.2018.1454739

Kearney, J., Muir, C., & Smith, K. (2021). Occupational injury among paramedics: A systematic review. Injury Prevention, injuryprev-2021-044405. https://doi.org/10.1136/injuryprev-2021-044405

MacQuarrie, A. (2019). Fit for duty: Context and correlates of paramedic health status and job performance, Charles Sturt University. Bathurst, NSW.

Miller, K., Baugh, C. W., Chai, P. R., Hasdianda, M. A., Divatia, S., Jambaulikar, G. D., & Boyer, E. W. (2021). Deployment of a wearable biosensor system in the emergency department: A technical feasibility study. Proceedings of the Annual Hawaii International Conference on System Sciences, 2021, 3567-3572.

Morales, L., McEachern, B. M., MacPhee, R. S., & Fischer, S. L. (2016). Patient acuity as a determinant of paramedics' frequency of being exposed to physically demanding work activities. Applied Ergonomics, 56, 187-193. https://doi.org/http://dx.doi.org/10.1016/j.apergo.2016.04.003

Moriarty, T. A., Feito, Y., Monahan, J., & Williamson, C. (2018). Using the Hexoskin smart garment to measure cardiorespiratory variables during high intensity functional training. Medicine & Science in Sports & Exercise, 50(5S), 673. https://doi.org/10.1249/01.mss.0000538220.84744.cc

Stryker. (2022). LIFEPAK® 15 monitor/defibrillator: Data sheet (No. 3341463-emea-en). Physio-Control, Inc. Retrieved October 29, 2025 from https://www.stryker.com/content/dam/stryker/ems/products/lifepak-15/eu/resources/3341463_emea-en_lifepak_15_data_sheet.pdf

Tobase, L., Cardoso, S. H., Rodrigues, R. T. F., Souza, D. R., Gugelmin-Almeida, D., Polastri, T. F., Peres, H. H. C., & Timerman, S. (2024). The application of the Borg scale in cardiopulmonary resuscitation: An integrative review. PLOS Digital Health, 3(8), e0000592. https://doi.org/10.1371/journal.pdig.0000592

Villar, R., Beltrame, T., & Hughson, R. L. (2015). Validation of the Hexoskin wearable vest during lying, sitting, standing and walking activities. Applied Physiology, Nutrition, and Metabolism. https://doi.org/10.1139/apnm-2015-0140