Assessing the Accuracy of ECG Chest Electrode Placement by EMS and Clinical Personnel Using Two Evaluation Methods
Main Article Content
Abstract
Background and purpose: A valid 12-lead electrocardiogram (ECG) depends on correct acquisition technique, particularly on the accurate location of precordial (chest) electrodes. The emergency medical services (EMS) segment of the care continuum is under-represented in previous clinically oriented studies of electrode placement. This study sought to assess the accuracy of chest electrode placement by EMS and clinical personnel in one geographic area, to identify patterns of misplacement to inform future training and continuing education, and to compare two methods of assessing electrode placement.
Methods: This prospective observational study recruited a convenience sample of EMS and clinical personnel. Participants placed simulated electrodes on a CPR-style manikin and completed a questionnaire about their training and experience. A subset also marked electrode locations on a printed diagram of the ribcage. Digitized placement data and questionnaire responses were analysed statistically.
Results: Findings from 149 participants showed misplacement patterns consistent with prior studies, with 41.6% rated as “acceptable” and 34.2% placing £ 3 electrodes acceptably. Correctness of electrode placement was comparable between EMS and clinical participants. More correct electrode placement correlated with classroom vs. on-the-job training, frequent vs. infrequent practice, and greater self-confidence. The diagram data collection method proved not equivalent to, and probably less reliable than, the hands-on manikin method for assessing placement skills.
Conclusions: Significant variation in ECG chest electrode placement by EMS personnel was comparable to that previously reported for clinical personnel, suggesting that existing concerns about placement errors by clinical personnel may apply equally to EMS personnel. More frequent practice and classroom-based initial ECG training were associated with significantly greater placement accuracy. Participants used diverse strategies to identify electrode locations. Further research is warranted to clarify optimal strategies for placing chest electrodes, especially on diverse body types. Sound initial ECG training and continuing education are necessary to reinforce high-quality ECG skills.
Article Details
This work is licensed under a Creative Commons Attribution-NoDerivatives 4.0 International License.
Publishing in IJOP allows authors to keep their copyright while giving IJOP unrestricted copyright permissions. Articles published in IJOP use Creative Common Attribution 4.0 International (CC BY-ND 4.0) licensing. This license requires that re-users give credit to the creator. It allows re-users to copy and distribute the material in any medium or format in unadapted form only, even for commercial purposes. Additional terms apply and can be accessed here.
Publishing in IJOP also allows authors to have contracts for non-exclusive distribution of the Journal's published version of the article, such as posting to an institutional repository or publication in a book, on the condition that the original publication in the original layout format in IJOP is retained and acknowledged.
We permit and encourage authors to post the articles they published in IJOP on their affiliated websites. This helps share the information, encourages citation in other works, and promotes scholarly discourse in the spirit of open access.
References
Abobaker. A., & Rana, R. M. (2021). V1 and V2 pericordial leads misplacement and its negative impact on ECG interpretation and clinical care [Letter]. Annals of Noninvasive Electrocardiology, 26:e12844. https://doi.org/10.1111/anec.12844
Aydemir, A. (2021). Evaluation of ECG recording applications of non-physician healthcare workers working in emergency departments. Anatolian Journal of Emergency Medicine, 4(4):125-131. https://doi.org/10.54996/anatolianjem.978965
Bickerton, M., & Pooler A. (2019). Misplaced ECG electrodes and the need for continuing training. British Journal of Cardiac Nursing, 14:123-132. https://doi.org/10.12968/bjca.2019.14.3.123
Bond, R. R., Finlay, D. D., Guldenring, D., Breen, C., & Moorhead, A. (2014, October 10) Utility and accuracy of online schematics that illustrate ECG electrode positions [Conference presentation abstract]. Medicine 2.0 Congress, Malaga, Spain. https://pure.ulster.ac.uk/en/publications/utility-and-accuracy-of-online-schematics-that-illustrate-ecg-ele-3
Bond, R. R., Finlay, D. D., Nugent, C. D., Breen, C., Guldenring, D., & Daly, M. J. (2012). The effects of electrode displacement on clinicians’ interpretation of the standard 12-lead electrocardiogram. European Journal of Internal Medicine, 23:610-615. https://doi.org/10.1016/j.ejim.2012.03.011
Brady, W. J., Harrigan, R. A., Chan, T. C., Custalow, C. B., Roberts, J. R., & Thomsen, T. W. (2019). Chapter 14. Basic Electrocardiographic Techniques. In J. R. Roberts, C. B. Custalow, & T. W. Thomsen. (Eds.), Roberts & Hedges’ clinical procedures in emergency medicine and acute care (7th ed.). Elsevier.
Cairns, C., & Kang, K. (2019). National Hospital Ambulatory Medical Care Survey: 2019 emergency department summary tables, Table 18. U.S. Department of Health and Human Services, National Institutes of Health, National Center for Health Statistics. https://doi.org/10.15620/cdc:115748
Campbell, B., Richley, D., Ross, C., & Eggett, C. J. (2017) Clinical guidelines by consensus: recording a standard 12-lead electrocardiogram. An approved method by the Society for Cardiological Science and Technology (SCST). Society for Cardiological Science and Technology. https://scst.org.uk/wp-content/uploads/2020/02/ SCST_ECG_Recording_Guidelines_2017am.pdf
Crawford, J., & Doherty, L. (2010). Ten steps to recording a standard 12-lead ECG. Practice Nursing, 21(12): 622-630. https://doi.org/10.12968/pnur.2010.21.12.622
Derkenne, C., Jost, D., Lefort, H., Tourtiere, J. P. (2017, December 5). Pathological ECG that seemed normal following electrode misplacement. BMJ Case Reports, https://doi.org/10.1136/bcr-2017-221429
Drew, B. J. (2008). Pseudomyocardial injury patterns because of nonstandard electrocardiogram electrode placement [Editorial]. Journal of Electrocardiology, 41:202-204. https://doi.org/10.1016/j.jelectrocard.2007.12.002
Garcia, T. (2015). Acquiring the 12-lead electrocardiogram: doing it right every time. Journal Emergency Nursing, 41:474-478. https://doi.org/10.1016/j.jen.2015.04.014
García-Niebla, J., Llontrop-García, P., Valle-Racero, J. I., Serra-Autonell, G., Batchvarov, V. N., & Bayes de Luna, A. (2009). Technical mistakes during the acquisition of the electrocardiogram. Annals of Noninvasive Cardiology, 14:389-403. https://doi.org/10.1111/j.1542-474X.2009.00328.x
Gianetta, N., Campagna, G., Di Muzio, F., Di Simone, E., Dionisi, S., & Di Muzio, M. (2020). Accuracy and knowledge in 12-lead ECG placement among nursing students and nurses: a web-based Italian study. Acta Biomedica for Health Professions, 91(12):e202004. https://doi.org/10.23750/abm.v91i12-S.10349
Goldberger, A. L., Goldberger, Z. D., & Shvilkin, A. (2023). Chapter 4: Electrocardiogram leads. In A. L. Goldberger, Z. D. Goldberger, & A. Shvilkin (Eds.), Goldberger’s clinical electrocardiography: a simplified approach (10th ed.). Elsevier.
Gregory, P., Kilner, T., Lodge, S., & Paget, S. (2021). Accuracy of ECG chest electrode placement by paramedics: an observational study. British Paramedic Journal, 6:8-14. https://doi.org/10.29045.14784726.2021.6.6.1.8
Harrigan, R. A., Chan, T. C., & Brady, W. J. (2012). Electrocardiographic electrode misplacement, misconnection, and artifact. Journal of Emergency Medicine, 43(6):1038-1044. https://doi.org/10.1016/j.jemermed.2012.02.024
Hayden, J. W., & Barney, J. (2018, November 27). ECG Educational Standards for Prehospital Providers. Journal of Emergency Medical Services. https://www.jems.com/patient-care/cardiac-resuscitation/ecg-educational-standards-for-prehospital-providers/#
Hoffman, I. (2008). Einthoven’s left foot: a plea for disciplined electrode placement [Editorial]. Journal of Electrocardiology, 41:205-206. https://doi.org/10.1016/j.jelectrocard.2007.12.003
Ilg, K. J., & Lehmann, M. H. (2012). Importance of recognizing pseudo-septal infarction due to electrocardiographic lead misplacement. American Journal of Medicine, 125(1):23-27 https://doi.org/10.1016/j.amjmed.2011.04.023; see also letters and responses, American Journal of Medicine, 125(9):E9-13, https://doi.org/10.1016/j.amjmed.2012.05.010
Kania, M., Rix, H., Fereniec, M., Zavala-Fernandez, H., Janusek, D., Mroczka, T., Stix, G., & Maniewski, R. (2014). The effect of precordial lead displacement on ECG morphology. Medical & Biological Engineering & Computing, 52:109-119. https://doi.org/10.1007/sl11517-013-1115-9
Kligfield, P., Gettes, L. S., Bailey, J. J., Childers, R., Deal, B. J., Hancock, E. W., van Herpen, G., Kors, J., Macfarlane, P., Mirvis, D. M., Pahlm, O., Rautaharju, P., & Wagner, G. S. (2007). Recommendations for the standardization and interpretation of the electrocardiogram: Part I: The electrocardiogram and its technology: A scientific statement from the American Heart Association Electrocardiography and Arrhythmia Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society. Journal of the American College of Cardiology, 49:1109-1127. https://doi.org/10.1016/j.jacc.2007.01.024
Longo, D., Poliserpi, C., Toscano Quilon, F., Díaz Uberti, P., López, C., García-Niebla, J., & Ramella, I. (2017). Diagnostical mistakes in ablation procedures associated with a high placement of the leads V1-V3. Journal of Electrocardiology, 50(4): 433-436. https://doi.org/10.1016/j.jelectrocard.2017.02.011
Macfarlane, P. W., Colaco, R., Stevens, K., Reay, P., Beckett, C., & Aitchison, T. (2003). Precordial electrode placement in women. Netherlands Heart Journal, 11(3):118-122. PMCID: PMC2499893; PMID: 25696193
McCann, K., Holdgate, A., Mahammad, R., & Waddington, A. (2007) Accuracy of ECG electrode placement by emergency department clinicians. Emergency Medicine Australasia, 19(5):442-448. https://doi.org/10.1111/j.1742-6723.2007.01004.x
McHugh, M. L. (2012). Interrater reliability: the kappa statistic. Biochemia Medica (Zagreb), 22(3):276-282. PMCID: PMC3900052; PMID: 23092060
McManus, J., Pfeifer, L., & Daya, M. (2004). Accuracy of ECG rhythm strip interpretation by firefighter-paramedics [Conference presentation abstract]. Prehospital Emergency Care, 8(1):93. https://doi.org/10.1080/312703003265
Medani, S., Hensey, H., Caples, N., & Owens, P. (2018). Accuracy in precordial ECG lead placement: improving performance through a peer-led educational intervention. Journal of Electrocardiology, 51:50-54. http://doi.org/10.1016/j.jelectrocard.2017.04.018
National Emergency Medical Services Information System. (n.d.) Retrieved May 2, 2023 from https://nemsis.org/view-reports/public-reports/ems-data-cube/
National Highway Traffic Safety Administration. National Emergency Medical Services Education Standards. (2021). U.S. Department of Transportation. https://www.ems.gov/assets/EMS_Education-Standards_2021_FNL.pdf
Rajaganeshan, R., Ludlam, C. L., Francis, D. P., Parasramka, S. P., & Sutton, R. (2008). Accuracy in ECG lead placement among technicians, nurses, general physicians and cardiologists. International Journal of Clinical Practice, 62:65-70. http://doi.org/10.1111/j.1742-1241.2007.01390.x
Rautaharju, P. M. (2008). Control of electrocardiography acquisition errors. Journal of Electrocardiology, 41(5):395-397. https://doi.org/10.1016/j.jelectrocard.2008.06.05
Rehman, M., & Rehman, N. U. (2020). Precordial ECG lead mispositioning: its incidence and estimated cost to healthcare. Cureus, 12:e9040. https://doi.org/10.7759/cureus.9040
Rosen, A. V., Koppikar, S., Shaw, C., & Baranchuk, A. (2014). Common ECG lead placement errors. Part II: precordial misplacements. International Journal of Medical Students, 2(3):99-103. https://doi.org/10.5195/ijms.2014.96
Rudiger, A., Hellermann, J. P., Mukherjee, R., Follath, F., & Turina, J. (2007). Electrocardiographic artifacts due to electrode misplacement and their frequency in different clinical settings. American Journal of Emergency Medicine, 25:174-178. https://doi.org/10.1016/j.ajem.2006.06.018
Santo, L., & Okeyode, T. (2018). National Ambulatory Medical Care Survey: 2018 National Summary Tables. Table 19. U.S. Department of Health and Human Services, National Institutes of Health, National Center for Health Statistics. https://www.emiccdc.gov/nchs/data/ahcd/namcs_summary/2018-namcs-web-tables-508.pdf
Toosi, M. S., & Sochanski, M. T. (2008). False ST elevation in a modified 12-lead surface electrocardiogram. Journal of Electrocardiology, 41:197-201. https://doi.org/10.1016/j.jelectrocard.2007.11.004
U.S. Census Bureau. (n.d.). U.S. and world population clock. U.S. Department of Commerce. Retrieved May 2, 2023 from https://www.census.gov/popclock/
Walsh, B. (2018). Misplacing V1 and V2 can have clinical consequences. American Journal of Emergency Medicine, 36(5):865-870. https://doi.org/10.1016/j.ajem.2018.02.006
Walsh, B., Sifford, D. P., Oto, B., Grauer, K., Digiulio, V. M., Watford, C. A., & Smith, S. W. (2017). Examples of precordial 12-lead electrocardiogram lead placement found on Google images are often incorrect and lack gender and racial diversity. 2017 SAEM annual meeting abstracts. Academic Emergency Medicine 24(S1):S105. https://doi.org/10.1111/acem.13203
Wolff, A. R., Long, S., McComb, J. M., Richley, D., & Mercer, P. (2012). The gap between training and provision: a primary-care based ECG survey in North-East England. British Journal of Cardiology, 19:38-40. https://doi.org/10.5837/bjc.2012.008